GE OEC 9800 Plus Manuals & User Guides User Manuals, Guides and Specifications for your GE OEC 9800 Plus Medical Equipment. Database contains 1 GE OEC 9800 Plus Manuals (available for free online viewing or downloading in PDF): Quick reference manual. GE OEC 9800 Plus Quick reference manual (4 pages) GE OEC 9800 Plus Manuals and User Guides. Where To Download Oec 9800 User Manual Oec 9800 User Manual Recognizing the artifice ways to get this ebook oec 9800 user manual is additionally useful. You have remained in right site to start getting this info. Get the oec 9800 user manual member that we give here and check out the link. You could buy lead oec 9800 user manual or acquire it.

Available Options

All OEC 9800 and 9900 systems go through a multistep refurbishing process. EDI takes great pride in the fact that each unit is restored to a like-new status. Pain Management, Orthopedic and Rehabilitation Services are just a few of the applications utilizing the EDI refurbished OEC 9800 C-arm. The rotating anode allows for greater penetration and resolution for the lumbar area, when performing localizations or other work involving the thicker anatomical areas. The 1K X 1K CCD technology used in the OEC 9800 image system allows for crisp, clear imaging. For whatever the purpose, an EDI refurbished OEC 9800 or 9900 will deliver the results you can depend on.

Mechanical repairs/cosmetic maintenance

  • All defective parts and covers are repaired or replaced
  • Monitor cart is disassembled and repainted or retouched as needed
  • X-ray tube removed and inspected for artifacts and internal integrity
  • Image intensifier removed and inspected for any imperfections and grid integrity
  • Camera removed, cleaned and tested Casters removed, cleaned and or replaced
  • Vertical lift assembly is tested for drift and adjusted/replaced if necessary
  • All bearings are inspected, cleaned and re-lubricated, or replaced as needed
  • Control panel display is tested and replaced if necessary
  • All locks and brake assemblies are inspected, cleaned, and repaired or replaced as needed
  • Steering is tested and adjusted as required
  • Foot switch and hand switch provided on each unit A complete set of operator and service manuals are provided

Oec 9800 User Manual User

Re-assembly

  • All components sent to C-arm reassembly area for rebuilding
  • Monitor cart rebuilt, II, tube, camera, main control and power cable installed
  • When C-arm is completely rebuilt mechanically, system is sent for calibration and final testing

Testing/calibration

  • Image intensifier and X-ray tube are tested for stability and balance
  • Image intensifier is tested for resolution and gain to be within OEM specifications
  • X-ray tube bearings are tested for noise and coast time
  • X-ray tube filaments and stator windings are tested
  • X-ray tube radiation output is verified to be within OEM specifications
  • X-ray generator high voltage tested
  • Maximum dose rate is set in compliance with government regulations
  • CCD camera calibrated to OEM specifications
  • X-ray beam is aligned for each field size
  • C-arm is tested for current leakage requirements
  • All monitors are aligned, resized, centered and focused
  • All monitors are adjusted for brightness and linearity
  • Video system is optimized for gray scale and resolution
  • All power supplies are tested and calibrated or replaced as necessary

Technical Specifications

Generator

  • High frequency generator 15kW full-wave
  • Up to 120 KVP and 75MA for radiographic exposures
  • Continuous fluro-mode up to 20 mA
  • One shot frame integration (low, medium, high)
  • Full power from standard 110V 15A Or 220V 8A outlet
  • Patented energy buffer design X-Ray Tube
  • Rotating anode X-ray tubeFocal spots: 0.3 - 0.6 mm
  • 300,000 HU Anode heat capacity

Physical Specifications

  • Free Space in Arc - 31”
  • Depth of Arc: 26”
  • Arc orbital movement: 115 Degrees
  • Left/Right wig-wag scan:+/- 20 degrees
  • Vertical Travel: 18” motorizedHorizontal travel: 8”
  • Lateral rotation: +/- 180 degrees

C-arm Dimensions

  • Length: 75.9”Height 69.9”
  • Width: 33”

Workstation Dimensions

  • Width: 27”
  • Height 64”
  • Depth: 27”
One moment please..
Not A Member?Sign Up

Oec 9800 User Manual Download

Ge oec 9800 user manual
DESCRIPTION
Sets the standard in mobile fluoroscopy and innovative X-ray imaging technology

The OEC 9800 Plus is a mobile imaging system that combines real-time 1k x 1k imaging resolution with a rotating anode X-ray tube and high powered 15 kW generator. This combination helps users see the details they need to see, even in very challenging imaging environments. The OEC 9800 Plus sets the standard for mobile imaging systems by providing image capture, recording and management capabilities comparable to the latest fixed-room fluoroscopic imaging systems at a significantly reduced cost.

FORUMSView All (64)
Ask a New Question

4

Replies
-RubenH
8 months ago
8 months agoService Manual
After replacing the 3 v battery for Bios and set up bios. Got system up but getting touch screen failure. Check all connections seems .OKReply
-Mikmaks
a year ago
a year agoAD Channel 8 Fail
Hi, Just wondering about 'AD Channel 8 fail' error that occurs on bootup. I've done some digging and found that it is sensing a possible voltage in the HV tank on bootup. Has anyone found a solution?Reply

0

Replies
-BILL LEE
a year ago
a year agoNot saving images or patients on saved exams
I have a 9800 plus c arm that is not saving any images or patients to the saved exams. If a doctor wants an image he immediately has to copy (print) the image and scan to PACS when done. When I press on the Customize button on the workstation and go under the Security tab. There is a Patient Health Information Delete All button. But when I press that none of the studies get errased. I do not know any other ways of deleting the patients or even if this will correct the issue. So help??Reply
DOCUMENTS / MANUALSView All


VIDEOS

FEATURES

  • Total redesign of current mobile C-arm equipment featuring 1K x 1K imaging resolution
  • 1K x 1K imaging resolution creates an expanded, more powerful platform.
  • Intuitive touch screen control offers simple system operation so it's easy to use by users of all levels of experience.
  • AutoTrak (TM) feature automatically tracks the subject anatomy anywhere within the imaging field for true point-and-shoot ease of use.
  • Low X-ray dose with high quality images
  • Backlit C-arm control panel to see in darkened operating rooms
  • Operator control panel on both sides of C-arm chassis conveniently located for operator use.
  • Triple the generator power.
  • Lightweight for ease in steering and maneuvering.

SPECIFICATIONS

Maximum Focal Spot0.3 mm Dual focal spots, 0,3mm/0.6mm
X-ray Generator Power Rating15 Kw

Additional Specifications

The OEC 9800 Plus is available with a 9001d or 12001d Image Intensifier and Standard or Super C configurations.
Cambria font mac. Hino jo8e engine repair manual.


  1. ESP Platform 0013 Standard features with a 1k x 1k 16 bit image processor.
  2. PM Care Platform 0013 Standard ESP features plus Real-time DSA and 8 FPS dynamic digital disk.
  3. Vascular Platform 0013 Upgrade to 15 fps, real-time subtraction, road mapping, peak opacification and variable landmarking.
NEWSView All
GE 9800 Plus Vs GE 9800 C-Arm – Comparing the Differences

We are frequently asked: “What’s the difference between the GE 9800 and 9800 plus C-Arm?” Well today we thought we would help our customers out by answering this question once and for all.

Device Alert

High-Voltage Bridge Driver May Not Conform to Safety Standards for Clearance and Creepage of Voltage Isolation, Potentially Leading to Loss of Imaging Functionality See attached PDF under Manuals & Resources tab